A sensor indicating when the wall panel button is pressed to toggle the door.
Client ID
1234
A unique identifier used to generate security + 2.0 codes
Closing duration
0.0 s
The amount of time it takes for the door to close (learned after one door cycle)
Door
OPEN | CLOSED
Discrete controls for the door.
- open the door, ignore if already opened.
- stop the door, only if door is moving.
- close the door, ignore if already closed.
Dry contact close
OFF | ON
The state of the ratgdo trigger door close input.
OFF - input is floating
ON - input is connected to GND
Dry contact light
OFF | ON
The state of the ratgdo trigger light input.
OFF - input is floating
ON - input is connected to GND
Dry contact open
OFF | ON
The state of the ratgdo trigger door open input.
OFF - input is floating
ON - input is connected to GND
Learn
OFF | ON
Put the GDO in learn mode (same as pressing the learn button)
Light
OFF | ON
Toggle the GDO's light on or off.
Lock remotes
UNLOCKED
Lockout the wireless remotes.
- lock the remotes. Wireless remotes will be ignored by
the GDO.
- unlock the remotes. The GDO will respond to commands
from wireless remotes.
Motion
OFF | ON
ON - Motion was detected by the wall control panel (on Sec + 1.0, triggers when the light turns
on)
Motor
OFF | ON
Indicates whether the GDO motor is running or not.
Obstruction
OFF | ON
Indicates whether the obstruction sensor beam is blocked by an object or not.
Opening duration
0.0 s
The amount of time it takes for the door to open (learned after one door cycle)
Openings
200 openings
The number of times the GDO has cycled
Paired Devices
6
The number of clients which are paired with the GDO.
Query Paired Devices
Send a query to the GDO to get the number of paired devices.
Query openings
Send a query to the GDO to get the current Openings count. This value is automatically updated
during normal status updates.
Query status
Get the current physical status of the garage door, light, wireless lockout, learn, openings,
etc.
Restart
Restart ratgdo
Rolling code counter
22 codes
The current rolling code counter for Security + 2.0, it's increemnted for each operation.
Safe mode boot
Restarts the device in a safe mode, useful if the device is missbehaving/crashing in a way that is preventing an Over-The-Air update to be performed.
Sync
Manually sync the ratgdo client with the GDO. If the GDO isn't responding to commands from
ratgdo, a sync should force them to be on the same rolling code counter.